Published October 2012 | Version v1
Journal article

An observational study to evaluate the efficiency and safety of ioversol pre-filled syringes compared with ioversol bottles in contrast-enhanced examinations

  • 1. Dept. of Diagnostic and Interventional Radiology, Johann Wolfgang Goethe Univ. Frankfurt, Frankfurt am Main (Germany)
  • 2. Dept. of Clinical Radiology, Univ. of Muenster, Munster (Germany)

Description

Background The use of pre-filled syringes for contrast media (CM) administration allows efficient and optimized workflow during radiologic diagnostic procedures, and reduces the risk of contamination, providing benefits for both patients and healthcare workers. Purpose To compare the efficiency and safety of ioversol (OptirayTM) bottles and pre-filled syringes in clinical practice. Material and Methods This was an observational, non-interventional, prospective, multicenter study conducted at 72 centers in Germany. Patients undergoing contrast-enhanced computed tomography (CT) examinations with ioversol were enrolled. The use of ioversol bottles and pre-filled syringes in the diagnostic procedure was recorded in terms of efficiency (residual volume, re-use of CM) and safety (adverse events [AEs]). Results A total of 10,836 patients were enrolled and included in this study. Ioversol bottles and syringes were used in 72% and 28% of cases, respectively. Analysis of the volume of CM in bottles before and after examinations, together with the volume used during the examination, suggested that in 22.5% of cases a new bottle was connected during the procedure. Further analysis revealed that in 80.2% of cases, the remaining volume of CM in the bottles could potentially be used for subsequent investigations, compared with <1% of cases for pre-filled syringes. For the total study population, AEs and serious AEs were reported in 30 (0.28%) and four (0.037%) patients, respectively, with no significant difference observed between ioversol bottles and syringes. Conclusion Administration of ioversol for contrast-enhanced CT examinations is associated with a low incidence of AEs and is generally safe and well tolerated. Ioversol pre-filled syringes were associated with lower residual volumes and less potential re-use compared with bottles

Availability note (English)

Available from DOI: http://dx.doi.org/10.1258/ar.2012.120303

Additional details

Identifiers

Publishing Information

Journal Title
Acta Radiologica (Online)
Journal Volume
53
Journal Issue
8
Journal Page Range
p. 914-920
ISSN
1600-0455

INIS

Country of Publication
Sweden
Country of Input or Organization
Sweden
INIS RN
44022831
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
COMPUTERIZED TOMOGRAPHY; CONTRAST MEDIA; EFFICIENCY; EVALUATION; SAFETY
Descriptors DEC
DIAGNOSTIC TECHNIQUES; TOMOGRAPHY