Temperature dependence of helium release from erbium tritide films

  • 1. Applied Physics Division 2353, Sandia National Laboratories, Albuquerque, New Mexico 87185

Description

The rates of helium release from ErT2 films were measured during constant temperature storage (ranging from 77--500 K) and following abrupt temperature changes. Large changes in helium release rates were measured immediately following the temperature changes; however, the helium release rates were only slightly temperature dependent following the initial transient response. The helium concentration which corresponds to the onset of accelerated release is found to be a function of temperature for ErT2 films. It is also shown that an ErT2 film that is in accelerated release can be made to release helium at a low rate after decreasing the helium concentration by means of a high-temperature cycle

Additional details

Publishing Information

Journal Title
J. Vac. Sci. Technol.
Journal Volume
19
Journal Issue
2
Series
J. Vac. Sci. Technol.
Journal Page Range
236-242
ISSN
0022-5355

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
12637700
Subject category
S36: MATERIALS SCIENCE;
Resource subtype / Literary indicator
Numerical Data
Descriptors DEI
DIFFUSION; ERBIUM COMPOUNDS; EXPERIMENTAL DATA; FILMS; HELIUM; TEMPERATURE DEPENDENCE; TRITIUM COMPOUNDS
Descriptors DEC
DATA; ELEMENTS; HYDROGEN COMPOUNDS; INFORMATION; NONMETALS; NUMERICAL DATA; RARE EARTH COMPOUNDS; RARE GASES