Published January 1997 | Version v1
Report

International neutron metrology in the LVR-15 research reactor

  • 1. Netherlands Energy Research Foundation (ECN), Petten (Netherlands)
  • 2. Nuclear Res. Inst., Rez (Czech Republic)

Description

A vertical channel in the reflector of the LVR-15 Research Reactor in NRI Rez was chosen for a neutron metrology comparison. The neutron spectrum is typical for a light water MTR. The calibration and quantification of the neutron field in the vertical channel can improve the quality of neutron measurements in NPP's and enhance the evaluation of operational and safety parameters. After a simultaneous irradiation, evaluations have been done by reactor dosimetry groups of NRI (Rez, Czech Republic) and ECN (Petten, the Netherlands). In the paper the experimental arrangement and techniques are described. Comparisons of the results are presented and discussed together with the results of some adjustments. (orig.)

Availability note (English)

Available from the authors at the Netherlands Energy Research Foundation (ECN), Petten (NL).

Additional details

Publishing Information

Imprint Pagination
12 p.
Report number
ECN-RX--97-003

Conference

Title
9. international symposium on reactor dosimetry.
Dates
2-6 Sep 1996.
Place
Prague (Czech Republic).