Published 1992 | Version v1
Miscellaneous

Structural design of large vertical spent fuel dry storage module

  • 1. Atomic Energy of Canada Ltd., Montreal, PQ (Canada). CANDU Operations
  • 2. Atomic Energy of Canada Ltd., Sheridan Park, ON (Canada). CANDU Operations

Description

CANSTOR is the large vertical spent fuel storage module developed at AECL CANDU for the storage of irradiated fuel from nuclear power plants. The heat removal concept used is based on convection cooling, which has proven to be more effective than conduction through a thickness of concrete. The more effective heat removal results in reduced temperature differentials across the wall thickness, and in lower reinforcement requirements. The structure consists of a concrete base slab, walls, and a roof, with inlet and outlet openings for cooling air circulation. This paper describes the structural analysis and design of the CANSTOR module using the finite-element method. 2 refs., 3 figs

Part of:
Proceedings of the 13. annual conference of the Canadian Nuclear Society. V. 1

Additional details

Publishing Information

Imprint Title
Proceedings of the 13. annual conference of the Canadian Nuclear Society. V. 1
Imprint Pagination
740 p.
Journal Page Range
[8 p.].
ISSN
0227-1907
Report number
INIS-mf--13960

Conference

Title
32. Annual conference of the Canadian Nuclear Association; 13. Annual conference of the Canadian Nuclear Society.
Dates
7-10 Jun 1992.
Place
Saint John, NB (Canada).

INIS

Country of Publication
Canada
Country of Input or Organization
Canada
INIS RN
25055654
Subject category
S42: ENGINEERING;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BUILDINGS; CONTAINERS; DESIGN; DRY STORAGE; DYNAMIC LOADS; FINITE ELEMENT METHOD; SPENT FUEL STORAGE; STORAGE FACILITIES
Descriptors DEC
CALCULATION METHODS; NUMERICAL SOLUTION; STORAGE

Optional Information