Dosimetry of the boron neutron capture reaction for BNCT and BNCEFNT
- 1. Wayne State Univ., Detroit, MI (United States)
- 2. Gershenson Radiation Oncology Center, Harper Hospital, Detroit, MI (United States)
Description
The use of paired proportional counters, constructed from A-150 tissue equivalent plastic (TEP) and A-150 TEP loaded with an appropriate amount of 10B (50 to 200 ppm), for the dosimetry of the boron neutron capture reaction has been investigated for several years at the Gershenson Radiation Oncology Center. This method has been used for determining the dose components (fast neutron, γ ray and boron capture product dose) in both Boron Neutron Capture Therapy (BNCT) beams and in beams proposed for boron neutron capture enhancement of fast neutron therapy (BNCEFNT). A disadvantage of this method, when standard 1/2'' diameter Rossi type proportional counters are used, is that the beam intensity must be relatively low in order to avoid saturation effects (pulse pile-up) in the counter. This is a major problem if measurements are to be made in a reactor beam, since reducing the beam intensity generally results in a change in the neutron spectrum. In order to overcome this problem, miniature cylindrical proportional counters have been developed which may be used in high intensity beams. The operational characteristics of these counters are compared with the standard 1/2'' spherical counters. A further disadvantage of proportional counters is the relatively long time it takes to collect data, particularly if detailed information (depth-dose curves and beam profiles) is required. This problem could be overcome by using a set of ionization chambers (an A-150 TEP chamber, a Mg chamber and a Mg chamber with a 25 μm boron loaded inner wall) which can be scanned in a water phantom. After calibration against the paired proportional counters it should be possible to extract the fast neutron, γ ray and boron neutron capture product doses from measurements made with these three ionization chambers. A set of such chambers has been used to make preliminary measurements in a fast neutron beam and the results of these measurements are presented. (orig.)
Additional details
Publishing Information
- Journal Title
- Strahlentherapie und Onkologie
- Journal Volume
- 175
- Journal Issue
- Suppl.2
- Journal Page Range
- p. 115-118
- ISSN
- 0179-7158
- CODEN
- STONE4
Conference
- Title
- 1. Med-AUSTRON conference
- Dates
- 8-11 Oct 1997
- Place
- Innsbruck (Austria)
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 30043796
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BORON 10; DOSIMETRY; EFFICIENCY; FAST NEUTRONS; IONIZATION CHAMBERS; MICRODOSIMETRY; NEUTRON CAPTURE THERAPY; NEUTRON REACTIONS; PROPORTIONAL COUNTERS; RADIATION DOSES; RADIOTHERAPY; TISSUE-EQUIVALENT MATERIALS
- Descriptors DEC
- BARYON REACTIONS; BARYONS; BORON ISOTOPES; DOSIMETRY; ELEMENTARY PARTICLES; FERMIONS; HADRON REACTIONS; HADRONS; ISOTOPES; LIGHT NUCLEI; MATERIALS; MEASURING INSTRUMENTS; MEDICINE; NEUTRON THERAPY; NEUTRONS; NUCLEAR REACTIONS; NUCLEI; NUCLEON REACTIONS; NUCLEONS; ODD-ODD NUCLEI; RADIATION DETECTORS; RADIOTHERAPY; STABLE ISOTOPES; THERAPY