Published December 2015
| Version v1
Journal article
Research on calculation method of spatial weighting function for ex-core detector
Creators
- 1. School of Nuclear Science and Engineering, Shanghai Jiao Tong University, Shanghai (China)
Description
The electric current of ex-core detector can be obtained from the scalar product of the spatial weighting function and the core power distribution. In this paper, the transportation calculation code DORT was used to evaluate spatial weighting function of the ex-core detector in two-dimensional geometry, and the cross sections were generated with the nuclear data library MATXS-47, which is processed from ENDF/B-Ⅶ.1. Applying the method to the Indian Point 2, the radial spatial weighting functions were calculated. The calculation results agree well with the reference values. (authors)
Additional details
Identifiers
Publishing Information
- Journal Title
- Atomic Energy Science and Technology
- Journal Volume
- 49
- Journal Issue
- 12
- Journal Page Range
- p. 2201-2204
- ISSN
- 1000-6931
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 51018459
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- CALCULATION METHODS; D CODES; ELECTRIC CURRENTS; NUCLEAR DATA COLLECTIONS; POWER DISTRIBUTION; PWR TYPE REACTORS; RADIATION DETECTORS; RESPONSE FUNCTIONS; TWO-DIMENSIONAL CALCULATIONS
- Descriptors DEC
- COMPUTER CODES; CURRENTS; ENRICHED URANIUM REACTORS; FUNCTIONS; MEASURING INSTRUMENTS; POWER REACTORS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 3 figs., 2 tabs., 5 refs.; http://dx.doi.org/10.7538/yzk.2015.49.12.2201