Published October 2014
| Version v1
Journal article
Study on RCP coupling interference assembling of CPR1000 nuclear power plant
Creators
- 1. China Nuclear Power Engineering Co., Ltd., Guangdong (China)
Description
Briefly introduce the CPR1000 main coolant pump (RCP) coupling assembly process, and analyzed the existing problems in the implementation process especially the disparity induced by the axial expansion. The improvement measures which primarily contain the domination of temperature and depth of the assembly are proposed and carried out the field application, and the expected effect is achieved. (authors)
Additional details
Publishing Information
- Journal Title
- Nuclear Power Engineering
- Journal Volume
- 35
- Journal Issue
- 5
- Journal Page Range
- p. 106-108
- ISSN
- 0258-0926
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 48083654
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- CHINA; INTERFERENCE; MACHINE PARTS; NUCLEAR POWER PLANTS; PRIMARY COOLANT CIRCUITS; PUMPS; PWR TYPE REACTORS; TEMPERATURE DEPENDENCE; THERMAL EXPANSION
- Descriptors DEC
- ASIA; COOLING SYSTEMS; ENERGY SYSTEMS; ENRICHED URANIUM REACTORS; EQUIPMENT; EXPANSION; NUCLEAR FACILITIES; POWER PLANTS; POWER REACTORS; REACTOR COMPONENTS; REACTOR COOLING SYSTEMS; REACTORS; THERMAL POWER PLANTS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 2 figs., 1 tab.