Published October 2018 | Version v1
Journal article

Thermodynamics and emission analysis of a modified Brayton cycle subjected to air cooling and evaporative after cooling

  • 1. KACST TIC on CCS and Mechanical Engineering Department, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)
  • 2. Mechanical Power Department, Faculty of Engineering, Cairo University, Giza 12613 (Egypt)

Description

Highlights: • Modified cycle performance was assessed theoretically from the energetic aspect. • Validation study was performed based on temperature and emission analysis. • Detailed energy analysis was conducted in terms of 1st and 2nd law efficiencies. • The effect of major parameters on the exergy destroyed of system components. • The theoretical measurement of nitrogen oxides and carbon monoxides were studied. - Abstract: In the current research, a gas turbine fueled by natural gas and integrated with the reversed Brayton cycle for cooling the intake air then evaporation was studied. The performance of the proposed cycle was assessed theoretically from energetic and environmental aspects. To achieve this, first a validation study has been performed based on temperature and emission analysis of a gas turbine model. Second, detailed energy analysis was conducted to identify the causes and locations of thermodynamic imperfection in terms of 1st and 2nd law efficiencies. Third, analytical relations for the theoretical measurement of two key emissions namely; Nitrogen Oxides and Carbon Monoxides were studied and applied. The effects of important influencing parameters such as the ambient temperature, ambient relative humidity, extracted mass rate and equivalence ratio on energy and environmental performance of the cycle was investigated. It was found that the proposed gas turbine cycle can bring down the emission levels to the regulatory standards (less than 35 ppm). It was also able to increase the power output by 31% with a slight drop in its efficiency. Therefore, the results of this research may be used to determine the range of operating parameters at which the gas turbine could be operated which can provide a considerable reduction in the emissions while maintaining a higher performance.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.enconman.2018.08.051

Additional details

Identifiers

DOI
10.1016/j.enconman.2018.08.051;
PII
S0196890418309002;

Publishing Information

Journal Title
Energy Conversion and Management
Journal Volume
174
Journal Page Range
p. 322-335
ISSN
0196-8904
CODEN
ECMADL

Optional Information

Notes
© 2018 Elsevier Ltd. All rights reserved.