Multi-contrast attenuation map synthesis for PET/MR scanners: assessment on FDG and Florbetapir PET tracers
Creators
- 1. University College London, Translational Imaging Group, Centre for Medical Image Computing, London (United Kingdom)
- 2. University College London, Dementia Research Centre, Institute of Neurology, London (United Kingdom)
- 3. University College London, Institute of Nuclear Medicine, London (United Kingdom)
- 4. University College London, Centre for Medical Imaging, London (United Kingdom)
- 5. University College London, Centre for Medical Image Computing, London (United Kingdom)
- 6. University of Wollongong, Centre for Medical Radiation Physics, Wollongong, NSW (Australia)
Description
Positron Emission Tomography/Magnetic Resonance Imaging (PET/MR) scanners are expected to offer a new range of clinical applications. Attenuation correction is an essential requirement for quantification of PET data but MRI images do not directly provide a patient-specific attenuation map. Methods We further validate and extend a Computed Tomography (CT) and attenuation map (μ-map) synthesis method based on pre-acquired MRI-CT image pairs. The validation consists of comparing the CT images synthesised with the proposed method to the original CT images. PET images were acquired using two different tracers (18F-FDG and 18F-florbetapir). They were then reconstructed and corrected for attenuation using the synthetic μ-maps and compared to the reference PET images corrected with the CT-based μ-maps. During the validation, we observed that the CT synthesis was inaccurate in areas such as the neck and the cerebellum, and propose a refinement to mitigate these problems, as well as an extension of the method to multi-contrast MRI data. Results With the improvements proposed, a significant enhancement in CT synthesis, which results in a reduced absolute error and a decrease in the bias when reconstructing PET images, was observed. For both tracers, on average, the absolute difference between the reference PET images and the PET images corrected with the proposed method was less than 2%, with a bias inferior to 1%. Conclusion With the proposed method, attenuation information can be accurately derived from MRI images by synthesising CT using routine anatomical sequences. MRI sequences, or combination of sequences, can be used to synthesise CT images, as long as they provide sufficient anatomical information. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00259-015-3082-xAdditional details
Identifiers
Publishing Information
- Journal Title
- European Journal of Nuclear Medicine and Molecular Imaging
- Journal Volume
- 42
- Journal Issue
- 9
- Journal Page Range
- p. 1447-1458
- ISSN
- 1619-7070
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 46116938
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; ALGORITHMS; ANATOMY; ATTENUATION; BRAIN; COMPUTERIZED TOMOGRAPHY; CORRECTIONS; ERRORS; FLUORINE 18; FLUORODEOXYGLUCOSE; IMAGE PROCESSING; MAGNETIC SUSCEPTIBILITY; NMR IMAGING; POSITRON COMPUTED TOMOGRAPHY; RADIOPHARMACEUTICALS; RELAXATION TIME; UPTAKE; VALIDATION; WEIGHTING FUNCTIONS
- Descriptors DEC
- ANTIMETABOLITES; BETA DECAY RADIOISOTOPES; BETA-PLUS DECAY RADIOISOTOPES; BIOLOGY; BODY; CENTRAL NERVOUS SYSTEM; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DRUGS; EMISSION COMPUTED TOMOGRAPHY; FLUORINE ISOTOPES; FUNCTIONS; HOURS LIVING RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; LABELLED COMPOUNDS; LIGHT NUCLEI; MAGNETIC PROPERTIES; MATERIALS; MATHEMATICAL LOGIC; NANOSECONDS LIVING RADIOISOTOPES; NERVOUS SYSTEM; NUCLEI; ODD-ODD NUCLEI; ORGANS; PHYSICAL PROPERTIES; PROCESSING; RADIOACTIVE MATERIALS; RADIOISOTOPES; TESTING; TOMOGRAPHY