Published April 1993
| Version v1
Journal article
An AC conduction pump with inductive reactive-power compensation
Description
Alternating-current conduction pumps are fully competitive for low hydraulic power, but have a major shortcoming: the low cos var-phi due to the unfavorable relation between the resistive and reactive power levels. In this work a pump is considered without allowance for the end effects with the armature compensated. The calculated results are applied to a three-phase conduction pump with intermediate transformer. The basic trends for such a pump with inductive compensation are calculated. The calculations show that the power factor can be raised substantially in a conduction pump by providing special inductive links between the winding phases. 7 refs., 4 figs
Additional details
Publishing Information
- Journal Title
- Magnetohydrodynamics
- Journal Volume
- 28
- Journal Issue
- 4
- Journal Page Range
- p. 408-413.
- ISSN
- 0024-998X
- CODEN
- MGHDAG
INIS
- Country of Publication
- Latvia
- Country of Input or Organization
- United States
- INIS RN
- 25013691
- Subject category
- S30: DIRECT ENERGY CONVERSION;
- Resource subtype / Literary indicator
- Translation
- Descriptors DEI
- ALTERNATING CURRENT; ELECTROMAGNETIC PUMPS; END EFFECTS; LIQUID METALS; MAGNETOHYDRODYNAMICS; MATHEMATICAL MODELS
- Descriptors DEC
- CURRENTS; ELECTRIC CURRENTS; ELEMENTS; EQUIPMENT; FLUID MECHANICS; FLUIDS; HYDRODYNAMICS; LIQUIDS; MECHANICS; METALS; PUMPS
Optional Information
- Notes
- Cover-to-cover Translation of Magnitnaya Gidrodinamika (USSR); Translated from Magnitnaya Gidrodinamika; No. 4, 101-106(Oct-Dec 1992).