Published April 1993 | Version v1
Journal article

An AC conduction pump with inductive reactive-power compensation

Description

Alternating-current conduction pumps are fully competitive for low hydraulic power, but have a major shortcoming: the low cos var-phi due to the unfavorable relation between the resistive and reactive power levels. In this work a pump is considered without allowance for the end effects with the armature compensated. The calculated results are applied to a three-phase conduction pump with intermediate transformer. The basic trends for such a pump with inductive compensation are calculated. The calculations show that the power factor can be raised substantially in a conduction pump by providing special inductive links between the winding phases. 7 refs., 4 figs

Additional details

Publishing Information

Journal Title
Magnetohydrodynamics
Journal Volume
28
Journal Issue
4
Journal Page Range
p. 408-413.
ISSN
0024-998X
CODEN
MGHDAG

INIS

Country of Publication
Latvia
Country of Input or Organization
United States
INIS RN
25013691
Subject category
S30: DIRECT ENERGY CONVERSION;
Resource subtype / Literary indicator
Translation
Descriptors DEI
ALTERNATING CURRENT; ELECTROMAGNETIC PUMPS; END EFFECTS; LIQUID METALS; MAGNETOHYDRODYNAMICS; MATHEMATICAL MODELS
Descriptors DEC
CURRENTS; ELECTRIC CURRENTS; ELEMENTS; EQUIPMENT; FLUID MECHANICS; FLUIDS; HYDRODYNAMICS; LIQUIDS; MECHANICS; METALS; PUMPS