Published 1993
| Version v1
Report
Open
Abort interlock diagnostic for protection of APS vacuum chamber
Description
The Advanced Photon Source (APS) vacuum system has been designed to be passively safe from bending magnet radiation heating at positron beam currents up to 30 mA. Above this value, certain components may be damaged from vertical beam missteering, although work is proceeding to raise the safe current threshold. Because of this, a system for preventing the misalignment of high power density beams is required. This report details a system for protection from dipole radiation only. Work on a system for ID radiation is continuing
Availability note (English)
MF available from INIS under the Report Number; OSTI as DE93015151; NTIS; INIS; US Govt. Printing Office Dep.Files
24072541.pdf
Files
(194.4 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:2e1c8c3c7fcc2c4d014e4ba16494fd1b
|
194.4 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 4 p.
- Report number
- ANL/ASD/CP--78290
Conference
- Title
- International particle accelerator conference.
- Dates
- 17-20 May 1993.
- Place
- Washington, DC (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 24072541
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ADVANCED PHOTON SOURCE; BEAM BENDING MAGNETS; DESIGN; DIAGNOSTIC TECHNIQUES; PRESSURE VESSELS; SAFETY; VACUUM SYSTEMS
- Descriptors DEC
- CONTAINERS; EQUIPMENT; MAGNETS; RADIATION SOURCES; STORAGE RINGS; SYNCHROTRON RADIATION SOURCES
Optional Information
- Contract/Grant/Project number
- Contract W-31109-ENG-38
- Funding organization
- USDOE, Washington, DC (United States).
- Secondary number(s)
- CONF-930511--137.