Published September 1989 | Version v1
Journal article

Measurement of the 90Sr half-life

  • 1. D.I. Mendeleyev Research Inst. of Metrology (VNIIM), Leningrad (USSR)

Description

Half-life measurements of 90Sr using 90Sr + 90Y solid sources with minimum impurities have been carried out at VNIIM. The half-life obtained is 29.2 years, with a standard deviation of 0.1 year. (orig.)

Additional details

Publishing Information

Journal Title
Metrologia
Journal Volume
26
Journal Issue
3
Series
Metrologia.
Journal Page Range
203-204
ISSN
0026-1394
CODEN
MTRGA