Results for the Aboveground Configuration of the Boiling Water Reactor Dry Cask Simulator
Creators
- 1. Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Nuclear Fuel Cycle Technologies
Description
The thermal performance of commercial nuclear spent fuel dry storage casks are evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission (NRC). Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating these models. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and also by increasing the internal convection through greater canister helium pressure. These same canistered cask systems rely on ventilation between the canister and the overpack to convect heat away from the canister to the environment for both above and belowground configurations. While several testing programs have been previously conducted, these earlier validation attempts did not capture the effects of elevated helium pressures or accurately portray the external convection of aboveground and belowground canistered dry cask systems. The purpose of the current investigation was to produce data sets that can be used to test the validity of the assumptions associated with the calculations used to determine steady-state cladding temperatures in modern dry casks that utilize elevated helium pressure in the sealed canister in an aboveground configuration. An existing electrically heated but otherwise prototypic BWR Incoloy-clad test assembly was deployed inside of a representative storage basket and cylindrical pressure vessel that represents a vertical canister system. The symmetric single assembly geometry with well-controlled boundary conditions simplifies interpretation of results. The arrangement of ducting was used to mimic conditions for an aboveground storage configuration in a vertical, dry cask systems with canisters. Transverse and axial temperature profiles were measured for a wide range of decay power and helium cask pressures. Of particular interest was the evaluation of the effect of increased helium pressure on peak cladding temperatures (PCTs) for identical thermal loads. All steady state peak temperatures and induced flow rates increased with increasing assembly power. Peak cladding temperatures decreased with increasing internal helium pressure for a given assembly power, indicating increased internal convection. In addition, the location of the PCT moved from near the top of the assembly to ~1/3 the height of the assembly for the highest (8 bar absolute) to the lowest (0 bar absolute) pressure studied, respectively. This shift in PCT location is consistent with the varying contribution of convective heat transfer proportional with of internal helium pressure.
Availability note (English)
Available from http://prod.sandia.gov/sand_doc/2016/169758.pdf; PURL: http://www.osti.gov/servlets/purl/1431490/Additional details
Identifiers
Publishing Information
- Imprint Pagination
- 50 p.
- Report number
- SAND--2016-9758
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 50020766
- Subject category
- S11: NUCLEAR FUEL CYCLE AND FUEL MATERIALS;
- Resource subtype / Literary indicator
- Non-conventional Literature
- Descriptors DEI
- BWR TYPE REACTORS; CASKS; CLADDING; DRY STORAGE; SPENT FUELS
- Descriptors DEC
- CONTAINERS; DEPOSITION; ENERGY SOURCES; ENRICHED URANIUM REACTORS; FUELS; MATERIALS; NUCLEAR FUELS; POWER REACTORS; REACTOR MATERIALS; REACTORS; STORAGE; SURFACE COATING; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Contract/Grant/Project number
- AC04-94AL85000
- Funding organization
- USDOE National Nuclear Security Administration (NNSA) (United States)
- Secondary number(s)
- OSTIID--1431490