Published December 1993 | Version v1
Report Restricted

Ferrocyanide Safety Program: Data requirements for the ferrocyanide safety issue developed through the data quality objectives (DQO) process

  • 1. Pacific Northwest Lab., Richland, WA (United States)
  • 2. Westinghouse Hanford Co., Richland, WA (United States)

Description

This document records the data quality objectives (DQO) process applied to the Ferrocyanide Waste Tank Safety Issue at the Hanford Site by the Pacific Northwest Laboratory and Westinghouse Hanford Company. Specifically, the major recommendations and findings from this Ferrocyanide DQO process are presented so that decision makers can determine the type, quantity, and quality of data required for addressing tank safety issues. The decision logic diagrams and error tolerance equations also are provided. Finally, the document includes the DQO sample-size formulas for determining specific tank sampling requirements

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE94005976; NTIS; US Govt. Printing Office Dep.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
76 p.
Report number
WHC-EP--0728

Optional Information

Contract/Grant/Project number
Contract AC06-87RL10930
Funding organization
USDOE, Washington, DC (United States).