Development of failed element monitoring system for PWR

  • 1. China Institute of Atomic Energy, Beijing (China)

Description

Aiming at the existent problems of failed element monitoring system in the PWR, the detector, the spiral tube, the neutron-moderator and the shielding of neutron bas improved on in this task. These improvements decrease the backgrounds effectively, raise the work stability of the detectors and resolve the failed element error action problem which can not be resolved for the long time, and the detecting sensitivity is raise ten times. The γ-ray detector is arranged spiral with outside, so the γ-rays with shorter half-life can be detected. The structure of gross gamma detection station has improved, so the solid angle is expanded, the transmissivity of γ-rays and β-rays are increased, and the ratio of signal to background is raised. The measurement instrument has been intellectualized. This system is above criticism for the users in operation. (authors)