Published May 15, 2007 | Version v1
Journal article

Temperature evaluation of an instrumented capsule after material irradiation tests in HANARO

  • 1. Korea Atomic Energy Research Institute, Deokjin-dong 150, Yuseong-gu, Daejeon 305-353 (Korea, Republic of)

Description

An instrumented capsule has been used for an irradiation test of various nuclear materials in the research reactor, HANARO. The capsule is designed to have a standard 4-hole structure for the economical test of an RPV material at 290 ± 10 deg. C. The temperature of the specimens for the reactor powers, 0-24 MW, is measured by 12 thermocouples, and finite element (FE) analyses are also performed to compare and verify the irradiation test results. As a result of the tests and analyses, the maximum temperature at the reactor power of 24 MW is 256 deg. C for an irradiation test and 202.6 deg. C for an FE analysis at Stage 3 of the capsule. Also, for each stage of the capsule, the temperature difference of the specimen in the axial direction is very small to within 10 deg. C. It is expected that the results presented in this paper will be useful when designing the instrumented capsules for an irradiation test

Additional details

Identifiers

DOI
10.1016/j.jnucmat.2006.10.019;
PII
S0022-3115(06)00544-7;

Publishing Information

Journal Title
Journal of Nuclear Materials
Journal Volume
362
Journal Issue
1
Journal Page Range
p. 19-25
ISSN
0022-3115
CODEN
JNUMAM

Optional Information

Copyright
Copyright (c) 2006 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.