Published December 2002
| Version v1
Journal article
The μ value and rays utilization rate of single plate source with dynamic irradiation
Creators
- 1. Irradiation Center of Hubei Province, Wuhan (China)
Description
The dose distribution of single plate source on the level direction and the vertical direction and μ value in goods box with dynamic irradiation were studied. The results shows that the function relation between the distance to single plate source and dose can be expressed as y=AeBx on the level direction and y=a+bx on the vertical direction. The μ value is 1.47 in dehydrated coriander box. The utilization rate of radioactive rays reached 21.6%
Additional details
Publishing Information
- Journal Title
- Acta Agriculturae Nucleatae Sinica
- Journal Volume
- 16
- Journal Issue
- 6
- Journal Page Range
- p. 370-375
- ISSN
- 1000-8551
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 34076477
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES;
- Descriptors DEI
- AVAILABILITY; COBALT 60; CORRELATION FUNCTIONS; DISTANCE; DYNAMIC PROGRAMMING; IRRADIATION DEVICES; LINEAR PROGRAMMING; NONUNIFORM IRRADIATION; RADIATION DOSES; REGRESSION ANALYSIS; SPATIAL DOSE DISTRIBUTIONS; VEGETABLES
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; COBALT ISOTOPES; DOSES; FOOD; FUNCTIONS; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; IRRADIATION; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; MATHEMATICS; MINUTES LIVING RADIOISOTOPES; NUCLEI; ODD-ODD NUCLEI; PLANTS; PROGRAMMING; RADIATION DOSE DISTRIBUTIONS; RADIOISOTOPES; STATISTICS; YEARS LIVING RADIOISOTOPES