The in-pile dosimetry of mixed radiations in the core of Triga Mark III nuclear reactor at ININ-Mexico
Creators
- 1. Instituto Nacional de Investigaciones Nucleares, Mexico City
Description
The isothermic calorimeters, one containing graphite and the other aluminum, were used to measure ionizing radiation doses received in three experimental positions of a TRIGA Mark III reactor core. The dose rates in the positions studied were found to be the following: Central Thimble (CT): (12.8+-0.3) x 105 Gy/h, 64% γ: 36% nsub(f); In-Core Isotope Production Facility (I-CIPF): (5.0+-0.1) x 105 Gy/h, 76%: 24% nsub(f); In-Pool Isotope Production Facility (I-PIPF): (2.0+-0.1) x 105 Gy/h, 80% γ: 20% nsub(f). The solid oxalic acid dosimetric technique was also utilized. Radiolytic decomposition constant (a) values observed in the experimental positions were the following: asub(CT)=17.64+-0.01 MGy; asub(I-CIPF)=17.4+-0.4 MGy; asub(I-PIPF)=17.6+-0.4 MGy. (author)
Additional details
Publishing Information
- Journal Title
- Rev. Mex. Fis.
- Journal Volume
- 31
- Journal Issue
- 2
- Series
- Rev. Mex. Fis.
- Journal Page Range
- 329-344
- ISSN
- 0035-001X
- CODEN
- RMXFA
INIS
- Country of Publication
- Mexico
- Country of Input or Organization
- Mexico
- INIS RN
- 17019823
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- CALORIMETRIC DOSEMETERS; CHEMICAL DOSEMETERS; DOSE RATES; SPATIAL DOSE DISTRIBUTIONS; TRIGA-3-SALAZAR REACTOR
- Descriptors DEC
- DISTRIBUTION; DOSEMETERS; ENRICHED URANIUM REACTORS; HOMOGENEOUS REACTORS; HYDRIDE MODERATED REACTORS; IRRADIATION REACTORS; ISOTOPE PRODUCTION REACTORS; MEASURING INSTRUMENTS; RADIATION DOSE DISTRIBUTIONS; REACTORS; RESEARCH AND TEST REACTORS; SOLID HOMOGENEOUS REACTORS; SPATIAL DISTRIBUTION; THERMAL REACTORS; TRIGA TYPE REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS