Published February 1985 | Version v1
Journal article

The in-pile dosimetry of mixed radiations in the core of Triga Mark III nuclear reactor at ININ-Mexico

  • 1. Instituto Nacional de Investigaciones Nucleares, Mexico City

Description

The isothermic calorimeters, one containing graphite and the other aluminum, were used to measure ionizing radiation doses received in three experimental positions of a TRIGA Mark III reactor core. The dose rates in the positions studied were found to be the following: Central Thimble (CT): (12.8+-0.3) x 105 Gy/h, 64% γ: 36% nsub(f); In-Core Isotope Production Facility (I-CIPF): (5.0+-0.1) x 105 Gy/h, 76%: 24% nsub(f); In-Pool Isotope Production Facility (I-PIPF): (2.0+-0.1) x 105 Gy/h, 80% γ: 20% nsub(f). The solid oxalic acid dosimetric technique was also utilized. Radiolytic decomposition constant (a) values observed in the experimental positions were the following: asub(CT)=17.64+-0.01 MGy; asub(I-CIPF)=17.4+-0.4 MGy; asub(I-PIPF)=17.6+-0.4 MGy. (author)

Additional details

Publishing Information

Journal Title
Rev. Mex. Fis.
Journal Volume
31
Journal Issue
2
Series
Rev. Mex. Fis.
Journal Page Range
329-344
ISSN
0035-001X
CODEN
RMXFA