Published 1981 | Version v1
Report Open

Methylamine-hydrogen exchange: Part II. Measurement of separation factors

  • 1. Bhabha Atomic Research Centre, Bombay (India). Heavy Water Div.

Description

Deuterium separation factors for the methylamine-hydrogen exchange process have been experimentally determined over a temperature range of -70deg to +55deg C and pressures from 0.5 to 100 bar, using metal as well as glass systems. Methylamine was kept in the liquid phase. These measured values have been found to be in very good agreement with the previously reported theoretical values. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

13702016.pdf

Files (233.0 kB)

Name Size Download all
md5:3fecee6ae9ce4100b9cb962348c2de76
233.0 kB Preview Download
Part of:
Methylamine-hydrogen exchange. Part I - theoretical evaluation of separation factors

Additional details

Publishing Information

Imprint Pagination
9 p.
Report number
BARC--1117

Optional Information

Notes
12 refs., 2 tables, 3 figures.