Assessment of physico-chemical and biokinetic properties of uranium peroxide hydrate UO4
Creators
- 1. Inst. de Protection et de Surete Nucleaire, Pierrelatte (France). Dept. de Protection de la Sante de l'Homme et de Dosimetrie
- 2. National Radiological Protection Board, Chilton (United Kingdom)
Description
Comprehensive studies on the radiotoxicological risk of an intermediate compound UO4, which is not specified in ICRP Recommendations, were motivated by its increased use in the nuclear fuel cycle and the lack of information such as physico-chemical and biokinetic properties. The aim of this work was to give an experimental basis for assessing the appropriate limits on intake for workers exposed to UO4 and to provide guidance for the interpretation of personal monitoring data. Particle size measurement of the UO4 dust indicated a geometric diameter D of 0.5 microm, which corresponds to an activity median aerodynamic diameter (AMAD) of 1.1 microm. In vitro experiments conducted in culture medium showed that UO4 is a soluble compound with 66.2% dissolved in 1.9 d and 33.8% in 78 d. Results of dissolution obtained with macrophages showed a significant decrease of 50% at 1 d in terms of solubility. Biokinetic data in the rat obtained from two in vivo studies involving intratracheal instillation in rats indicated half-times in the lung of 0.5 d and 27 d for an initial lung deposit (ILD) of 195 microg, and 1.2 d and 38 d for an ILD of 7.6 microg. Absorption parameters to blood as defined in the ICRP Publication 66 human respiratory tract model were calculated with the specific software GIGAFIT and led to the rapid fraction fr, the rapid rate sr, and the slow rate ss. Effective dose coefficients by inhalation for this UO4 compound using the in vivo experimental results were calculated to be between 0.52 and 0.70 x 10-6 Sv Bq-1. Comparison of these values with effective dose coefficients defined in ICRP Publication 68 for workers showed that UO4 could be considered as a fast soluble compound of Type F
Additional details
Publishing Information
- Journal Title
- Health Physics
- Journal Volume
- 75
- Journal Issue
- 4
- Journal Page Range
- p. 389-397
- ISSN
- 0017-9078
- CODEN
- HLTPAO
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 30001703
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S38: RADIATION CHEMISTRY, RADIOCHEMISTRY AND NUCLEAR CHEMISTRY;
- Descriptors DEI
- BIOASSAY; CHEMICAL PROPERTIES; INHALATION; OCCUPATIONAL SAFETY; PERSONNEL MONITORING; PHYSICAL PROPERTIES; RADIATION DOSES; RADIONUCLIDE KINETICS; URANIUM PEROXIDE
- Descriptors DEC
- ACTINIDE COMPOUNDS; INTAKE; KINETICS; MONITORING; OXYGEN COMPOUNDS; PERFORMANCE TESTING; PEROXIDES; RADIATION MONITORING; SAFETY; TESTING; URANIUM COMPOUNDS