Comparison of 2D radiography and a semi-automatic CT-based 3D method for measuring change in dorsal angulation over time in distal radius fractures
Creators
- 1. Uppsala University, Department of Orthopaedics, Uppsala (Sweden)
- 2. Uppsala University, Centre for Image Analysis, Uppsala (Sweden)
- 3. Uppsala University, Uppsala Clinical Research Centre, UCR Statistics, Uppsala (Sweden)
Description
The aim of the present study was to compare the reliability and agreement between a computer tomography-based method (CT) and digitalised 2D radiographs (XR) when measuring change in dorsal angulation over time in distal radius fractures. Radiographs from 33 distal radius fractures treated with external fixation were retrospectively analysed. All fractures had been examined using both XR and CT at six times over 6 months postoperatively. The changes in dorsal angulation between the first reference images and the following examinations in every patient were calculated from 133 follow-up measurements by two assessors and repeated at two different time points. The measurements were analysed using Bland-Altman plots, comparing intra- and inter-observer agreement within and between XR and CT. The mean differences in intra- and inter-observer measurements for XR, CT, and between XR and CT were close to zero, implying equal validity. The average intra- and inter-observer limits of agreement for XR, CT, and between XR and CT were ± 4.4 , ± 1.9 and ± 6.8 respectively. For scientific purpose, the reliability of XR seems unacceptably low when measuring changes in dorsal angulation in distal radius fractures, whereas the reliability for the semi-automatic CT-based method was higher and is therefore preferable when a more precise method is requested. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00256-016-2350-6Additional details
Identifiers
Publishing Information
- Journal Title
- Skeletal Radiology
- Journal Volume
- 45
- Journal Issue
- 6
- Journal Page Range
- p. 763-769
- ISSN
- 0364-2348
- CODEN
- SKRADI
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 47080777
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ALIGNMENT; AUTOMATION; BIOMEDICAL RADIOGRAPHY; BONE FRACTURES; BONE JOINTS; COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; DIMENSIONS; IMAGE PROCESSING; MEASURING METHODS; RELIABILITY; THREE-DIMENSIONAL CALCULATIONS; TWO-DIMENSIONAL CALCULATIONS; X-RAY RADIOGRAPHY
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; DISEASES; EVALUATION; INDUSTRIAL RADIOGRAPHY; INJURIES; MATERIALS TESTING; MEDICINE; NONDESTRUCTIVE TESTING; NUCLEAR MEDICINE; ORGANS; PROCESSING; RADIOLOGY; SKELETON; TESTING; TOMOGRAPHY