Description

Comparative clearance determinations with a partially shielded whole-body counter, a shoulder probe, a gamma camera and also exclusively by use of the plasma activity concentration at 45 min p.i. revealed the following results: The partially shielded whole-body counter can be substituted by the shoulder probe without major loss of quality, provided that this is taken into consideration in the subsequent calculations. However, values below 250 ml/min may possibly be wrong, i.e. too high, when the camera background-curve is used for clearance determination. The very simple 45-min-clearance is recommended mostly as a method in addition or in reserve. (orig.)

Abstract (German)

Vergleichende Clearancebestimmungen mit Ganzkoerpermessstand, Schultersonde, Gammakamera sowie auch allein mit Hilfe der Plasmaaktivitaetskonzentration 45 min p.i. brachten folgende Ergebnisse: Der Ganzkoerpermessstand laesst sich ohne groessere Qualitaetseinbussen durch eine Schultersonde ersetzen, wenn dies bei der weiteren Auswertung in geeigneter Weise beruecksichtigt wird. Hingegen koennen bei der Clearancebestimmung mittels Kamerauntergrundkurve schon Werte unterhalb von 250 ml/min unter Umstaenden eindeutig falsch, d.h. zu hoch, sein. Die sehr einfache 45-min-Clearance empfiehlt sich vor allem als Zusatz- oder Reservemethode. (orig.)

Additional details

Additional titles

Original title (German)
Einfache nuklearmedizinische Nierenclearancemethoden im Vergleich

Publishing Information

Journal Title
Nuklearmedizin
Journal Volume
23
Journal Issue
3
Series
CODEN: NUKLD.;Nuklearmedizin.
Journal Page Range
155-160
ISSN
0029-5566