Loss of DHR sequences at Browns Ferry Unit One - accident-sequence analysis
Description
This study describes the predicted response of Unit One at the Browns Ferry Nuclear Plant to a postulated loss of decay heat removal (DHR) capability following scram from full power with the power conversion system unavailable. In accident sequences without DHR capability, the residual heat removal (RHR) system functions of pressure suppression pool cooling and reactor vessel shutdown cooling are unavailable. Consequently, all decay heat energy is stored in the pressure suppression pool with a concomitant increase in pool temperature and primary containment pressure. With the assumption that DHR capability is not regained during the lengthy course of this accident sequence, the containment ultimately fails by overpressurization. Although unlikely, this catastrophic failure might lead to loss of the ability to inject cooling water into the reactor vessel, causing subsequent core uncovery and meltdown. The timing of these events and the effective mitigating actions that might be taken by the operator are discussed in this report
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A09/MF A01; 1 as DE83012314.
Files
Additional details
Publishing Information
- Imprint Pagination
- 176 p.
- Report number
- NUREG/CR--2973
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 14787213
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- AFTER-HEAT REMOVAL; BROWNS FERRY-1 REACTOR; COMPUTER CALCULATIONS; CONTAINMENT SYSTEMS; FAILURES; HEAT TRANSFER; HYDRAULICS; PRESSURE GRADIENTS; PRESSURE SUPPRESSION; REACTOR ACCIDENTS; REACTOR SAFETY; SPATIAL DISTRIBUTION; TEMPERATURE DISTRIBUTION
- Descriptors DEC
- ACCIDENTS; BWR TYPE REACTORS; CONTAINMENT; DISTRIBUTION; ENERGY TRANSFER; ENRICHED URANIUM REACTORS; MIXED SPECTRUM REACTORS; POWER REACTORS; REACTORS; SAFETY; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Secondary number(s)
- ORNL/TM--8532.