Published 1975 | Version v1
Report

High resolution readout system for drift chambers

  • 1. Stanford Linear Accelerator Center, Calif. (USA)
  • 2. Cornell Univ., Ithaca, N.Y. (USA)

Description

The development of a readout system for drift chambers has been reported. One of drift chamber systems will be located inside a solenoid magnet with a field of 5 kilogauss. The amplifier - discriminator will be mounted directly on the chambers so that only logic level signals will be transmitted to the time digitizer location about 25 m away. The schematics of the time - to - analog part of the time degitizer, its analog - to - digital converter and memory are presented and outlined. The readout of the memory is by standard CAMAC techniques. Electronics will be made in the CAMAC standard too

Additional details

Additional titles

Original title (no language)
Proportsional'nye i drejfovye kamery.

Publishing Information

Imprint Title
Proportional and drift chambers
Imprint Pagination
p. 224-227.
Report number
JINR-D--13-9164

Conference

Title
International meeting on proportional and drift chambers.
Dates
17 - 20 Jun 1975.
Place
Dubna, USSR.

INIS

Country of Publication
USSR
Country of Input or Organization
USSR
INIS RN
9386848
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CAMAC SYSTEM; DIGITIZERS; DRIFT CHAMBERS; MAGNETIC FIELDS; READOUT SYSTEMS
Descriptors DEC
MEASURING INSTRUMENTS; MULTIWIRE PROPORTIONAL CHAMBER; PROPORTIONAL COUNTERS; RADIATION DETECTORS

Optional Information

Notes
3 figs. Imprint:Proportsional'nye i drejfovye kamery.