Optimal energy window selection of a CZT-based small-animal SPECT for quantitative accuracy

  • 1. Department of Radiological Science and Research Institute of Health Science, Yonsei University, Wonju 220-710 (Korea, Republic of)
  • 2. Department of Nuclear Medicine, College of Medicine, Hanyang University Hospital, Seoul 133-792 (Korea, Republic of)
  • 3. Laboratory animal center, OSONG Medical Innovation Foundation, Chunguk 363-951 (Korea, Republic of)
  • 4. Molecular Imaging Research Center, Korea Institute of Radiological and Medical Sciences, Seoul 139-706 (Korea, Republic of)

Description

Cadmium zinc telluride (CZT)-based small-animal single-photon emission computed tomography (SPECT) has desirable characteristics such as superior energy resolution, but data acquisition for SPECT imaging has been widely performed with a conventional energy window. The aim of this study was to determine the optimal energy window settings for technetium-99 m (99mTc) and thallium-201 (201Tl), the most commonly used isotopes in SPECT imaging, using CZT-based small-animal SPECT for quantitative accuracy. We experimentally investigated quantitative measurements with respect to primary count rate, contrast-to-noise ratio (CNR), and scatter fraction (SF) within various energy window settings using Triumph X-SPECT. The two ways of energy window settings were considered: an on-peak window and an off-peak window. In the on-peak window setting, energy centers were set on the photopeaks. In the off-peak window setting, the ratios of energy differences between the photopeak from the lower- and higher-threshold varied from 4:6 to 3:7. In addition, the energy-window width for 99mTc varied from 5% to 20%, and that for 201Tl varied from 10% to 30%. The results of this study enabled us to determine the optimal energy windows for each isotope in terms of primary count rate, CNR, and SF. We selected the optimal energy window that increases the primary count rate and CNR while decreasing SF. For 99mTc SPECT imaging, the energy window of 138–145 keV with a 5% width and off-peak ratio of 3:7 was determined to be the optimal energy window. For 201Tl SPECT imaging, the energy window of 64–85 keV with a 30% width and off-peak ratio of 3:7 was selected as the optimal energy window. Our results demonstrated that the proper energy window should be carefully chosen based on quantitative measurements in order to take advantage of desirable characteristics of CZT-based small-animal SPECT. These results provided valuable reference information for the establishment of new protocol for CZT-based small-animal study, and may offer insights into the potential of multiple-isotope imaging with CZT-based small-animal SPECT

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nima.2015.02.018

Additional details

Identifiers

DOI
10.1016/j.nima.2015.02.018;
PII
S0168-9002(15)00199-0;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
782
Journal Page Range
p. 104-111
ISSN
0168-9002
CODEN
NIMAER

Optional Information

Copyright
Copyright (c) 2015 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.