Published July 1988 | Version v1
Report Open

Design proposal for a JFT-2M TV Thomson scattering system

  • 1. Princeton Univ., NJ (USA). Plasma Physics Lab.

Description

A design for the optics of a TV Thomson scattering system for JFT-2M is presented, which will measure electron temperature and density profiles having up to 82 points, spanning the horizontal mid plane of the machine. A detailed design for the collecting optics is presented since it is critical to the success of the system. It is shown that the Bouwers type catadioptric collection optics can be color corrected allowing the system to be used over a wide wavelength range. The laser requirements are presented and are easily met with commercially available systems. Two sketches of spectrometer designs are presented for two different sizes of detector. The detector gating and readout requirements are presented and can be met in existing detector systems. The importance of developing larger area detectors is emphasized and a possible detector system is presented. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

20004573.pdf

Files (516.9 kB)

Name Size Download all
md5:2fb8156d437ebe9cd806378ea1d466df
516.9 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
23 p.
Report number
JAERI-M--88-137