Published 1999 | Version v1
Computer medium

Enhanced safety margins under beyond-design-basis accident conditions for PWRs with eight accumulators. Transient studies in the PKL-test facility

  • 1. Siemens AG, Power Generation Group (KWU), Erlangen (Germany)

Description

The integral test facility PKL at Siemens/KWU in Erlangen, Germany, simulates a 1300 MWe Siemens-type PWR with four symmetrically arranged primary loops. It is equipped with eight accumulators. In the test PKL III D6.l a station blackout transient was simulated, which means loss of auxiliary power and simultaneous failure of the D1- and D2-emergency power systems. The loss of the heat sink led to primary heat-up, depletion of coolant inventory by discharge at the pressurizer safety valve and finally to core uncovery. When the core outlet temperatures (fluid) were 50 K above saturation, an accident management procedure was performed by a primary bleed-and-feed. For the bleed the pressurizer valve station was opened completely (corresponding to 100 cm2 in the PWR). The pressure decreased. At 26 bar a passive feed from the eight accumulators started. The injected water reestablished core cooling and accelerated the depressurization. The pressure decreased down to 10 bar. In this paper the test results are described and analyzed. They are compared to a PKL-test with only four accumulators at the hot legs assumed to be available, that was performed earlier. The comparison demonstrates an enhanced inherent safety of PWRs with eight accumulators as compared to those with four. (author)

Part of:
ICONE-7: Proceedings of the 7th international conference on nuclear engineering

Additional details

Publishing Information

Publisher
Japan Society of Mechanical Engineers
Imprint Place
Tokyo (Japan)
Imprint Title
ICONE-7: Proceedings of the 7th international conference on nuclear engineering
Imprint Pagination
4252 p.
Journal Page Range
[10 p.]

Conference

Title
7. international conference on nuclear engineering
Acronym
ICONE-7
Dates
19-23 Apr 1999
Place
Tokyo (Japan)

Optional Information

Notes
This CD-ROM can be used for WINDOWS 95/98/NT, MACINTOSH and UNIX; Acrobat Reader 3.0.1 is included; Data in PDF format, Track No. 07, ICONE-7076