Towards integration of PET/MR hybrid imaging into radiation therapy treatment planning

  • 1. Institute of Medical Physics, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen 91052 (Germany)
  • 2. Section for Biomedical Physics, University Hospital for Radiation Oncology, Eberhard Karls University Tübingen, Tübingen 72076 (Germany)
  • 3. Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens-Foundation, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University Tübingen, Tübingen 72076 (Germany)
  • 4. Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tübingen, Tübingen 72076 (Germany)
  • 5. High Field and Hybrid MR-Imaging, University Hospital Essen, Essen 45147 (Germany)
  • 6. Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen 45141 (Germany)

Description

Purpose: Multimodality imaging has become an important adjunct of state-of-the-art radiation therapy (RT) treatment planning. Recently, simultaneous PET/MR hybrid imaging has become clinically available and may also contribute to target volume delineation and biological individualization in RT planning. For integration of PET/MR hybrid imaging into RT treatment planning, compatible dedicated RT devices are required for accurate patient positioning. In this study, prototype RT positioning devices intended for PET/MR hybrid imaging are introduced and tested toward PET/MR compatibility and image quality. Methods: A prototype flat RT table overlay and two radiofrequency (RF) coil holders that each fix one flexible body matrix RF coil for RT head/neck imaging have been evaluated within this study. MR image quality with the RT head setup was compared to the actual PET/MR setup with a dedicated head RF coil. PET photon attenuation and CT-based attenuation correction (AC) of the hardware components has been quantitatively evaluated by phantom scans. Clinical application of the new RT setup in PET/MR imaging was evaluated in anin vivo study. Results: The RT table overlay and RF coil holders are fully PET/MR compatible. MR phantom and volunteer imaging with the RT head setup revealed high image quality, comparable to images acquired with the dedicated PET/MR head RF coil, albeit with 25% reduced SNR. Repositioning accuracy of the RF coil holders was below 1 mm. PET photon attenuation of the RT table overlay was calculated to be 3.8% and 13.8% for the RF coil holders. With CT-based AC of the devices, the underestimation error was reduced to 0.6% and 0.8%, respectively. Comparable results were found within the patient study. Conclusions: The newly designed RT devices for hybrid PET/MR imaging are PET and MR compatible. The mechanically rigid design and the reproducible positioning allow for straightforward CT-based AC. The systematic evaluation within this study provides the technical basis for the clinical integration of PET/MR hybrid imaging into RT treatment planning

Additional details

Identifiers

Publishing Information

Journal Title
Medical Physics
Journal Volume
41
Journal Issue
7
Journal Page Range
p. 072505-072505.12
ISSN
0094-2405
CODEN
MPHYA6

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
46118334
Subject category
S60: APPLIED LIFE SCIENCES;
Descriptors DEI
ACCURACY; COMPARATIVE EVALUATIONS; HEAD; IMAGE PROCESSING; NECK; NMR IMAGING; PATIENTS; PHANTOMS; RADIOTHERAPY
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; EVALUATION; MEDICINE; MOCKUP; NUCLEAR MEDICINE; PROCESSING; RADIOLOGY; STRUCTURAL MODELS; THERAPY

Optional Information

Notes
(c) 2014 American Association of Physicists in Medicine