Published June 2014 | Version v1
Journal article

Value of non-contrast sequences in magnetic resonance angiography of hepatic arterial vasculature

  • 1. Department of Diagnostic Radiology, Yale School of Medicine, Box 208042, Tompkins East 2, 333 Cedar Street, New Haven, CT 06520-8042, United States of America (United States)
  • 2. Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Francis Street, Boston, MA 02115, United States of America (United States)
  • 3. Department of Radiology, Columbia University Medical Center, Milstein 3rd Fl, New York NY 10032 United States (United States)
  • 4. Department of Diagnostic Radiology, Yale School of Medicine, Box 208042, Tompkins East 2, 333 Cedar St, New Haven, CT 06520-8042, United States of America (United States)

Description

Objective: To evaluate value of adding non-contrast MR angiographic sequence (In-Flow Inversion Recovery [IFIR]) to standard fat-suppressed T1-weighted postcontrast sequence (3D spoiled gradient echo [3D-GRE]) for evaluating hepatic arterial anatomy. Methods: Retrospective evaluation of 30 consecutive patients undergoing multiphase liver MRI. Individual vessels for IFIR/3D-GRE sequences were evaluated by two blinded readers using a four-point scale. Statistical analysis was performed using the Wilcoxon signed-rank test for vessel conspicuity between IFIR/3D-GRE sequences. Results: IFIR alone diagnostically imaged 8.1% of vessels, 3D-GRE alone 25.8%, 55.8% by both 3D-GRE/IFIR, and 10.3% of vessels by neither. Two patients with variant vascular anatomy were visualized with both sequences. Addition of IFIR to 3D-GRE resulted in statistically significant increase in arterial visualization (p < 0.001), 10% relative increase in identified vessels, and 3–5 mi increase in acquisition time for total scan time of 30–35 min. Conclusions: IFIR may be a useful adjunct to 3D-GRE in hepatic angiography without adding considerably to scan time. 10% more hepatic arteries were seen when combining information from IFIR/3D-GRE vs. 3D-GRE alone

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ejrad.2014.03.013

Additional details

Identifiers

DOI
10.1016/j.ejrad.2014.03.013;
PII
S0720-048X(14)00151-X;

Publishing Information

Journal Title
European Journal of Radiology
Journal Volume
83
Journal Issue
6
Journal Page Range
p. 905-908
ISSN
0720-048X
CODEN
EJRADR

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
47005346
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ANATOMY; ARTERIES; BIOMEDICAL RADIOGRAPHY; EVALUATION; LIVER; MAGNETIC RESONANCE; NMR IMAGING; PATIENTS
Descriptors DEC
BIOLOGY; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; GLANDS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RESONANCE

Optional Information

Copyright
Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.