Published May 2006 | Version v1
Miscellaneous

Sizing techniques for crack indications od eddy current data in steam generator tubes

  • 1. Korea Electric Power Research Institute, Daejeon (Korea, Republic of)

Description

This paper describes the sizing methodology for stress corrosion cracking which lies in steam generator tubes. It is not easy to analyze exactly the depth and length of the crack from the eddy current data. The crack-sizing for the steam generator tube during the in-service inspection was not performed until July 2005 in Korea. However it is necessary to evaluate the depth and length of the crack in order to complete the condition monitoring and operational assessment of the Steam Generator Management Program. The currently available crack-sizing techniques were introduced from Electric Power Research Institute. Prior to applying to the field analysis, the round robin tests for those techniques were carried out by the domestic analysts. The results suggest that it is necessary to develop new techniques since the deviations for some types of crack are relatively large.

Part of:
Proceedings of the Korean Society for Nondestructive Testing Spring Meeting 2006

Additional details

Publishing Information

Publisher
KSNT
Imprint Place
Seoul (Korea, Republic of)
Imprint Title
Proceedings of the Korean Society for Nondestructive Testing Spring Meeting 2006
Imprint Pagination
442 p.
Journal Page Range
p. 428-432

Conference

Title
2006 Spring Meeting of the Korean Society for Nondestructive Testing
Dates
11-12 May 2006
Place
Seoul (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
45098320
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
CRACKS; EDDY CURRENTS; MONITORING; STEAM GENERATORS; TUBES
Descriptors DEC
BOILERS; CURRENTS; ELECTRIC CURRENTS; VAPOR GENERATORS

Optional Information

Notes
4 refs, 4 figs, 2 tabs