Published January 1979 | Version v1
Report Open

Temperature and thermal stress analysis of a switching tube anode

Description

In the design of high power density switching tubes which are subjected to cyclic thermal loads, the temperature induced stresses must be minimized in order to maximize the life expectancy of the tube. Following are details of an analysis performed for the Magnetic Fusion Program at the Lawrence Livermore Laboratory on a proposed tube. The tube configuration is given. The problem was simplified to one-dimensional approximations for both the thermal and stress analyses. The underlying assumptions and their implications are discussed

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A03/MF A01.

Files

10453576.pdf

Files (490.0 kB)

Name Size Download all
md5:dd2edcdc73753cb1c0e2097f2f175d84
490.0 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
32 p.
Report number
UCID--18049

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
10453576
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Descriptors DEI
ANODES; ELECTRON TUBES; ONE-DIMENSIONAL CALCULATIONS; POWER SUPPLIES; STRESS ANALYSIS; SWITCHES; THERMAL STRESSES; THERMONUCLEAR REACTORS
Descriptors DEC
ELECTRICAL EQUIPMENT; ELECTRODES; ELECTRONIC EQUIPMENT; STRESSES