Temperature and thermal stress analysis of a switching tube anode
Description
In the design of high power density switching tubes which are subjected to cyclic thermal loads, the temperature induced stresses must be minimized in order to maximize the life expectancy of the tube. Following are details of an analysis performed for the Magnetic Fusion Program at the Lawrence Livermore Laboratory on a proposed tube. The tube configuration is given. The problem was simplified to one-dimensional approximations for both the thermal and stress analyses. The underlying assumptions and their implications are discussed
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A03/MF A01.Files
10453576.pdf
Files
(490.0 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:dd2edcdc73753cb1c0e2097f2f175d84
|
490.0 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 32 p.
- Report number
- UCID--18049
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 10453576
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- ANODES; ELECTRON TUBES; ONE-DIMENSIONAL CALCULATIONS; POWER SUPPLIES; STRESS ANALYSIS; SWITCHES; THERMAL STRESSES; THERMONUCLEAR REACTORS
- Descriptors DEC
- ELECTRICAL EQUIPMENT; ELECTRODES; ELECTRONIC EQUIPMENT; STRESSES