Published November 1, 2014 | Version v1
Journal article

Statistical Modeling of CTV Motion and Deformation for IMRT of Early-Stage Rectal Cancer

  • 1. Department of Radiotherapy, University Medical Center Utrecht, Utrecht (Netherlands)
  • 2. Delft Institute of Applied Mathematics, Delft University of Technology, Delft (Netherlands)

Description

Purpose: To derive and validate a statistical model of motion and deformation for the clinical target volume (CTV) of early-stage rectal cancer patients. Methods and Materials: For 16 patients, 4 to 5 magnetic resonance images (MRI) were acquired before each fraction was administered. The CTV was delineated on each MRI. Using a leave-one-out methodology, we constructed a population-based principal component analysis (PCA) model of the CTV motion and deformation of 15 patients, and we tested the model on the left-out patient. The modeling error was calculated as the amount of the CTV motion-deformation of the left-out-patient that could not be explained by the PCA model. Next, the PCA model was used to construct a PCA target volume (PCA-TV) by accumulating motion-deformations simulated by the model. A PCA planning target volume (PTV) was generated by expanding the PCA-TV by uniform margins. The PCA-PTV was compared with uniform and nonuniform CTV-to-PTV margins. To allow comparison, geometric margins were determined to ensure adequate coverage, and the volume difference between the PTV and the daily CTV (CTV-to-PTV volume) was calculated. Results: The modeling error ranged from 0.9 ± 0.5 to 2.9 ± 2.1 mm, corresponding to a reduction of the CTV motion-deformation between 6% and 60% (average, 23% ± 11%). The reduction correlated with the magnitude of the CTV motion-deformation (P<.001, R=0.66). The PCA-TV and the CTV required 2-mm and 7-mm uniform margins, respectively. The nonuniform CTV-to-PTV margins were 4 mm in the left, right, inferior, superior, and posterior directions and 8 mm in the anterior direction. Compared to uniform and nonuniform CTV-to-PTV margins, the PCA-based PTV significantly decreased (P<.001) the average CTV-to-PTV volume by 128 ± 20 mL (49% ± 4%) and by 35 ± 6 mL (20% ± 3.5%), respectively. Conclusions: The CTV motion-deformation of a new patient can be explained by a population-based PCA model. A PCA model-generated PTV significantly improved sparing of organs at risk compared to uniform and nonuniform CTV-to-PTV margins

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ijrobp.2014.06.040

Additional details

Identifiers

DOI
10.1016/j.ijrobp.2014.06.040;
PII
S0360-3016(14)03412-9;

Publishing Information

Journal Title
International Journal of Radiation Oncology, Biology and Physics
Journal Volume
90
Journal Issue
3
Journal Page Range
p. 664-672
ISSN
0360-3016
CODEN
IOBPD3

Optional Information

Copyright
Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.