Comparative Study of Tritium Analysis Method with High-Volume Counting Vial
Creators
- 1. Korea Institute of Geoscience and Mineral Resources, Daejeon (Korea, Republic of)
Description
Tritium (3H) analysis in groundwater was difficult because of its low activity. Therefore, the electrolytic enrichment method was used. To improve the detection limit and for performing simple analysis, a high-volume counting vial with the available liquid scintillation counter (LSC) was investigated. Further, it was compared with a conventional 20-mL counting vial. The LSC with the electrolytic enrichment method was used 3H analysis in groundwater. A high-volume 145-mL counting vial was compared with a conventional 20-mL counting vial to determine the counting characteristics of different LSCs. When a Quantulus LSC was used, the counting window between channels 35 and 250 was used. The background count was approximately 1.86 cpm, and the counting efficiency increased from 8% to 40% depending on the mixing ratio of the volume of sample and cocktail solution. For LSC-LB7, the optimum counting window was between 1 and 4.9 keV, which was selected by the factory (Hitachi Aloka Medical Ltd., Japan) by considering quenching using a standard external gamma source. The background count of LSC-LB7 was approximately 3.60 ± 0.29 cpm when the 145-mL vial was used and 2.22 ± 0.17 cpm when the 20-mL vial was used. The minimum detectable activity (MDA) of the 20-mL vial was greater for LSC-LB7 than for Quantulus. The MDA with the 145-mL vial was improved to 0.3 Bq/L when compared with the value of 1.6 Bq/L for the 20-mL vial. The counting efficiency when using the 145-mL vial was 27%, whereas it was 18% when using the 20-mL vial. This difference can be attributed to the vial volume. The figure of merit (FOM) of the 145-mL vial was four times greater than that of the 20-mL vial because the volume of the former vial is approximately seven times greater than that of the latter. Further, the MDA for 3H decreased from 1.6 to 0.3 Bq/L. The counting efficiency and FOM of LSC-LB7 was slightly less than those of Quantulus when the 20-mL vial was used. The background counting rate of the Quantulus was lower than that of the LSC-LB7
Additional details
Publishing Information
- Journal Title
- Journal of Radiation Protection and Research (2016)
- Journal Volume
- 45
- Journal Issue
- 3
- Series
- 14 refs, 2 figs, 2 tabs
- Journal Page Range
- p. 142-146
- ISSN
- 2508-1888
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 52113656
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES; S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- APPROXIMATIONS; COMPARATIVE EVALUATIONS; COST; COUNTING RATES; DATA; ECONOMICS; EFFICIENCY; ENRICHMENT; GAMMA SOURCES; GROUND WATER; LIQUID SCINTILLATION DETECTORS; MIXING RATIO; PERFORMANCE; QUENCHING; SENSITIVITY; SOCIO-ECONOMIC FACTORS; SOLUTIONS; STANDARDS; TRITIUM; WINDOWS
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; CALCULATION METHODS; DIMENSIONLESS NUMBERS; DISPERSIONS; EVALUATION; HOMOGENEOUS MIXTURES; HYDROGEN COMPOUNDS; HYDROGEN ISOTOPES; INFORMATION; INSTITUTIONAL FACTORS; ISOTOPES; LIGHT NUCLEI; MEASURING INSTRUMENTS; MIXTURES; NUCLEI; ODD-EVEN NUCLEI; OPENINGS; OXYGEN COMPOUNDS; RADIATION DETECTORS; RADIATION SOURCES; RADIOISOTOPES; SCINTILLATION COUNTERS; WATER; YEARS LIVING RADIOISOTOPES