Published July 2021 | Version v1
Journal article

Axial strength of Zircaloy-4 samples with reduced thickness after a simulated loss of coolant accident

  • 1. IRSN, Saint Paul-Lez-Durance (France)

Description

To investigate wall-thinning impact on axial load resistance of Zircaloy-4 cladding rods after a LOCA transient, axial tensile samples have been machined on as-received tubes with reduced thicknesses between 370 and 580 μm. After high temperature oxidation under steam at 1200 ℃ with measured ECR ranging from 10 to 18% and water quenching, machined samples were axially loaded until fracture. These tests were modeled using a fracture mechanics approach developed in a previous study. Fracture stresses are rather well predicted. However, the slightly lower fracture stress observed for wall-thinned samples is not anticipated by this modeling approach. The results from this study confirm that characterizing the axial load resistance using semi-integral tests including the creep and burst phases was the best option to obtain accurate axial strengths describing accurately the influence of wall-thinning at burst region

Additional details

Publishing Information

Journal Title
Nuclear Engineering and Technology
Journal Volume
53
Journal Issue
7
Series
19 refs, 9 figs, 3 tabs
Journal Page Range
p. 2295-2303
ISSN
1738-5733