Published November 1998 | Version v1
Report

Safety analyses for the new fuel at the Dukovany NPP (units 1 - 4) - uncontrolled opening of the steam dump to condenser

Description

Analyses of uncontrolled opening of all steam dumps to the condenser were carried out for units 3 and 4 with a view to ascertaining whether a sufficient reactor core cooling would be secured and the pressure in the primary circuit would remain below 110% of the design value. The acceptability criteria were found to be satisfied. Although the reactor remained critical for the entire period analyzed, the operator would have time enough to bring the reactor to the subcritical state. (P.A.)

Availability note (English)

Available from Nuclear Research Institute Rez, 250 68 Rez, Czech Republic; e-mail contact: ret@nri.cz

Additional details

Additional titles

Original title (Czech)
Bezpecnostni analyzy pro nove palivo JE Dukovany (1.-4. blok) - nerizene otevreni PSK

Publishing Information

Imprint Pagination
[58 p.]
Report number
UJV--11169-T(Rev.1)

Optional Information

Notes
7 tabs., 63 figs., 12 refs.