Published July 8, 1992 | Version v1
Report Open

Reduced length design of 9.8 MHz APS/PAR accelerator cavity

Description

The Accelerator cavities in this report can be modeled as a circuit with transmission line sections and lumped elements. Two configuration of the reduced length coaxial cavities are discussed; the folded cavity and the radial line loaded gap cavity are compared with design equations. The APS PAR 9.8 MHz first harmonic cavity is designed in the two configurations and compared. Since capacitive loading in the reduced length cavities involves use of radial transmission line structure, the properties of radial transmission line are discussed. The results of URMELT simulations are presented and compared

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE95015395; NTIS; US Govt. Printing Office Dep.

Files

27008366.pdf

Files (395.4 kB)

Name Size Download all
md5:ba921a7e0bf9f47a74e5004fa3e0c1a8
395.4 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
17 p.
Report number
LS--211

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
27008366
Subject category
S43: PARTICLE ACCELERATORS; S43: PARTICLE ACCELERATORS;
Descriptors DEI
ADVANCED PHOTON SOURCE; CAVITY RESONATORS; DESIGN; IMPEDANCE; MATHEMATICAL MODELS; RF SYSTEMS
Descriptors DEC
ELECTRONIC EQUIPMENT; EQUIPMENT; RADIATION SOURCES; RESONATORS; STORAGE RINGS; SYNCHROTRON RADIATION SOURCES

Optional Information

Contract/Grant/Project number
Contract W-31-109-ENG-38
Funding organization
USDOE, Washington, DC (United States).