Ultracold neutron extraction at the ITEPh reactor

Description

A facility for ultracold neutron (UCN) extraction from the ITEP heavy water reactor vertical channel is described. The facility consists of a UCN source-beryllium converter cooled with gaseous helium at 150-160 K; an oilless vacuum system based on adsorption pumps which maintains the vacuum at the level of 10-3-10-4 tor; and an external neutron guide. The UCN integral flux at the neutron guide outlet approximately 200 n/c . It is pointed out that reduction of the converter temperature up to 20-30 K and improvement of the neutronguide quality may it possible to attain the UCN flux approximately (1-2)x103 n/c

Availability note (English)

MF available from INIS under the Report Number.

Files

13670803.pdf

Files (256.2 kB)

Name Size Download all
md5:0e20cf29d2e14d2e5c6b77a2801fc21d
256.2 kB Preview Download

System files (12.6 kB)

Name Size Download all

Additional details

Additional titles

Original title (Russian)
Вывод ультрахолодных нейтронов на реакторе ИТЭФ

Publishing Information

Imprint Pagination
8 p.
Report number
ITEF--17(1981)

Optional Information

Notes
4 refs.; 3 figs.