Assessment of cirrhotic liver enhancement with multiphasic computed tomography using a faster injection rate, late arterial phase, and weight-based contrast dosing
Creators
- 1. Dalhousie Univ., QE II Health Sciences Centre, Dept. of Diagnostic Radiology, Halifax, NS (Canada)
Description
Purpose: This study aimed to update our liver computed tomography (CT) protocol according to published guidelines, and to quantitatively evaluate the effect of these modifications. Methods: The modified liver CT protocol employed a faster injection rate (5 vs 3 mL/s), later arterial phase (20-second vs 10-second postbolus trigger), and weight-based dosing of iodinated contrast (1.7 mL/kg vs 100 mL fixed dose). Liver and vascular attenuation values were measured on CTs of patients with cirrhosis from January to September 2015 (old protocol, n = 49) and from October to December 2015 (modified protocol, n = 31). CTs were considered adequate if liver enhancement exceeded 50 Hounsfield units (HU) in portal venous phase, or when the unenhanced phase was unavailable, if a minimum iodine concentration of 500 mg I/kg was achieved. Attenuations and iodine concentrations were compared using the t test and the number of suboptimal studies was compared with Fisher's exact test. Results: CTs acquired with the modified protocol demonstrated higher aortic (P = .001) and portal vein (P < .0001) attenuations in the arterial phase as well as greater hepatic attenuation on all postcontrast phases (P = .0006, .002, and .003 for arterial, venous, and equilibrium phases, respectively). Hepatic enhancement in the portal venous phase (61 ± 15 HU vs 51 ± 16 HU; P =.0282) and iodine concentrations (595 ± 88 mg I/kg vs 456 ± 112 mg I/kg; P < .0001) were improved, and the number of suboptimal studies was reduced from 57% to 23% (P = .01). Conclusions: A liver CT protocol with later arterial phase, faster injection rate, and weight-based dosing of intravenous contrast significantly improves liver enhancement and iodine concentrations in patients with cirrhosis, resulting in significantly fewer suboptimal studies. (author)
Availability note (English)
Available from doi: http://dx.doi.org/10.1016/j.carj.2017.01.001Additional details
Identifiers
Publishing Information
- Journal Title
- Canadian Association of Radiologists Journal
- Journal Volume
- 68
- Journal Issue
- 4
- Journal Page Range
- p. 371-378
- ISSN
- 0846-5371
INIS
- Country of Publication
- Canada
- Country of Input or Organization
- Canada
- INIS RN
- 51028767
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- COMPUTERIZED TOMOGRAPHY; CONTRAST MEDIA; LIVER; LIVER CIRRHOSIS; RECOMMENDATIONS
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; DIGESTIVE SYSTEM DISEASES; DISEASES; GLANDS; ORGANS; TOMOGRAPHY
Optional Information
- Notes
- 45 refs., 4 tabs., 4 figs.