Double-supply-frequency pressure pulsation in annular linear induction pump. Pt. I. Measurement and numerical analysis
- 1. Central Research Inst. of Electric Power Industry, Abiko, Chiba (Japan)
- 2. STC 'Sintez', D.V. Efremov Institute of Electrophysical Apparatus, St. Petersburg (Russian Federation)
Description
This paper describes an experimental and analytical study of double-supply-frequency pressure pulsation arising in an annular linear induction pump. In a large-scale induction pump, it is known that the supply frequency should be relatively low in order to satisfy a magnetohydrodynamic stability criterion. Under such a low supply frequency, however, double-supply-frequency pressure and flow rate pulsation generated in an induction pump may be of concern. The experimental data obtained in the present work shows that the amplitude of the pressure pulsation increases with decreasing supply frequency, number of poles and/or slip. The numerical result reveals that the pressure pulsation comes from a disturbance of the electromagnetic force near the stator ends. (orig.)
Additional details
Publishing Information
- Journal Title
- Nuclear Engineering and Design
- Journal Volume
- 195
- Journal Issue
- 1
- Journal Page Range
- p. 85-100
- ISSN
- 0029-5493
- CODEN
- NEDEAU
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Switzerland
- INIS RN
- 31008634
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Descriptors DEI
- COOLING; FLUID FLOW; INDUCTION; MAGNETOHYDRODYNAMICS; MEASURING INSTRUMENTS; NUCLEAR POWER PLANTS; PRESSURE MEASUREMENT; PUMPS; SIMULATION
- Descriptors DEC
- EQUIPMENT; FLUID MECHANICS; HYDRODYNAMICS; MECHANICS; NUCLEAR FACILITIES; POWER PLANTS; THERMAL POWER PLANTS
Optional Information
- Notes
- 12 refs.