Published November 9, 1978 | Version v1
Report Restricted

LOFT calibration tube thermal expansion analysis

Description

This analysis is in response to a request to determine the maximum relative linear displacement of the lower end of the calibration tube towards the bottom of the guide tube that can occur during any operating mode of the LOFT reactor. It was found that the worst case occurs during nuclear test L2-4 with a maximum displacement of 0.78 inches at 40 seconds. This is a conservative value and no factors should be applied for analysis uncertainties

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
18 p.
Report number
LTR--1111-57

Optional Information

Secondary number(s)
RE-A--78-230.