Published 1986 | Version v1
Report Open

Improvement transition x-ray abilities in modern installations

Description

It is shown that in facilities containing except for calorimeters, muon and track detectors also detectors of X-ray transient radiation (XRTR) the latter are capable of carrying out simalteneously particle identification and muon energy measurement. Four-module XRTR detector designed for hadron-electron rejection with a coefficient of an order of 300 at Ee,h <or approx. 30 GeV/c and ∼ 30 at Ee,h ∼ 100 GeV/c with electron detection efficiency of 90% has been considered. Each module contains a radiator and a multiwire proportional chamber. Polypropylene cotton was used as the radiator

Files

19033422.pdf

Files (334.5 kB)

Name Size Download all
md5:55ba2bb649c9584bfc5a8005beaf4111
334.5 kB Preview Download

System files (14.7 kB)

Name Size Download all

Additional details

Additional titles

Original title (Russian)
Расширение возможностей RPI-детекторов в современных установках

Publishing Information

Imprint Pagination
10 p.
Report number
EFI--946(97)-86

Optional Information

Notes
3 refs.; 3 figs.