Liquid volume measurement method for the picoliter to nanoliter volume range based on quartz crystal microbalance technology
Creators
- 1. Laboratory for MEMS Applications, IMTEK, Department of Microsystems Engineering, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg (Germany)
- 2. HSG-IMIT, Institut für Mikro- und Informationstechnik, Georges-Koehler-Allee 103, 79110 Freiburg (Germany)
Description
In this article, a quantitative liquid volume measurement method for the sub-nanoliter range using a quartz crystal microbalance (QCM) is described and experimentally analyzed. The primary measurement device to determine the volume of small liquid droplets is a QCM sensor coated with a surface-attached hydrogel to improve the mechanical coupling of the liquid to the sensor surface. An experimental evaluation of measured volumes in the range of 3 nl to 15 nl in normal room conditions has been performed with three identical sensors prepared with a PDMAA-1%MaBP hydrogel coating with a thickness of 1.5 µm ± 0.12 µm. A linearity of R2 more than 0.87, an average coefficient of variation (CV) within one experimental run of 5.7%, a mean absolute relative bias of 5.5%, and a sensor-to-sensor variation of 6.3% have been experimentally determined. The feasibility of this method has also been experimentally proven for the picoliter volume range down to 200 pl, with an average CV of 5.3% and a mean absolute relative bias of 6.5%. Furthermore, a stability evaluation consisting of 10 experimental series with approximately 150 measurements over the course of one week has been performed. This evaluation showed that the experimental setup, although exhibiting highly consistent performance within one measurement run, is not yet reproducible enough for long-term and repeated use because of undefined swelling and crack formation in the hydrogel layer. The low reproducibility implies a relatively high expanded uncertainty, with k = 2 according to the JCGM 'Evaluation of Measurement Data—Guide to the Expression of Uncertainty in Measurement' (GUM) for the total measurement method of approximately 3.82 nl when measuring a 10 nl liquid droplet. Nevertheless, the QCM method as described here contributes to significant progress beyond the state-of-the-art that might allow new opportunities for precise measurement of sub-nanoliter liquid volumes. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/0957-0233/25/9/095302Additional details
Identifiers
Publishing Information
- Journal Title
- Measurement Science and Technology
- Journal Volume
- 25
- Journal Issue
- 9
- Journal Page Range
- [9 p.]
- ISSN
- 0957-0233
- CODEN
- MSTCEP
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47067112
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S75: CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SUPERFLUIDITY;
- Descriptors DEI
- APPROXIMATIONS; CRACK PROPAGATION; CRYSTALS; DATA COVARIANCES; DROPLETS; EVALUATION; LAYERS; LIQUIDS; MICROBALANCES; QUARTZ; SENSORS; SURFACES; SWELLING; THICKNESS
- Descriptors DEC
- BALANCES; CALCULATION METHODS; DEFORMATION; DIMENSIONS; FLUIDS; MEASURING INSTRUMENTS; MINERALS; OXIDE MINERALS; PARTICLES; WEIGHT INDICATORS