MRI of meniscal bucket-handle tears
Creators
- 1. Menorah Medical Center, Overland Park, KS (United States). Dept. of Radiology
Description
A meniscal bucket-handle tear is a tear with an attached fragment displaced from the meniscus of the knee joint. Low sensitivity of MRI for detection of bucket-handle tears (64% as compared with arthroscopy) has been reported previously. We report increased sensitivity for detecting bucket-handle tears with the use of coronal short tau inversion recovery (STIR) images. Results. By using four criteria for diagnosis of meniscal bucket-handle tears, our overall sensitivity compared with arthroscopy was 93% (28 of 30 meniscal bucket-handle tears seen at arthroscopy were detected by MRI). The meniscal fragment was well visualized in all 28 cases on coronal STIR images. The double posterior cruciate ligament sign was seen in 8 of 30 cases, the flipped meniscus was seen in 10 of 30 cases and a fragment in the intercondylar notch was seen in 18 of 30 cases. (orig.)
Additional details
Publishing Information
- Journal Title
- Skeletal Radiology
- Journal Volume
- 27
- Journal Issue
- 9
- Journal Page Range
- p. 495-499
- ISSN
- 0364-2348
- CODEN
- SKRADI
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 29061789
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BONE JOINTS; CORONARIES; LIGAMENTS; NMR IMAGING; SENSITIVITY
- Descriptors DEC
- ANIMAL TISSUES; ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; CONNECTIVE TISSUE; DIAGNOSTIC TECHNIQUES; ORGANS; SKELETON