Response analysis of TLD-300 dosimeters in heavy-particle beams
- 1. Universite Catholique de Louvain, Cliniques Universitaires Saint Luc, Service de Radiotherapie Oncologique, UCL 10/4752, Avenue Hippocrate 10, 1200 Bruxelles (Belgium)
- 2. Universite Catholique de Louvain, Cliniques Universitaires Saint Luc, Unite de Radiobiologie et de Radioprotection, RBNT 5469, Avenue Hippocrate 54, 1200 Bruxelles (Belgium)
Description
In vivo dosimetry is recommended as part of the quality control procedure for treatment verification in radiation therapy. Using thermoluminescence, such controls are planned in the p(65)+Be neutron and 85 MeV proton beams produced at the cyclotron at Louvain-La-Neuve and dedicated to therapy applications. A preliminary study of the peak 3 (150 deg. C) and peak 5 (250 deg. C) response of CaF2:Tm (TLD-300) to neutron and proton beams aimed to analyse the effect of different radiation qualities on the dosimetric behaviour of the detector irradiated in phantom. To broaden the range of investigation, the study was extended to an experimental C-12 heavy ion beam (95 MeV/nucleon). The peak 3 and 5 sensitivities in the neutron beam, compared to Co-60, varied little with depth. A major change of peak 5 sensitivity was observed for samples positioned under five leaves of the multi-leaf collimator. While peak 3 sensitivity was constant with depth in the unmodulated proton beam, peak 5 sensitivity increased by 15%. Near the Bragg peak, peak 3 showed the highest decrease of sensitivity. In the modulated proton beam, the sensitivity values were not significantly smaller than those measured in the unmodulated beam far from the Bragg peak region. The ratio of the heights of peak 3 and peak 5 decreased by 70% from the Co-60 reference radiation to the C-12 heavy-ion beam. This parameter was strongly correlated with the change of radiation quality. (author)
Additional details
Publishing Information
- Journal Title
- Physics in Medicine and Biology (Online)
- Journal Volume
- 41
- Journal Issue
- 9
- Journal Page Range
- p. 1665-1678
- ISSN
- 1361-6560
INIS
- Country of Publication
- International Atomic Energy Agency (IAEA)
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 31025282
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- BRAGG CURVE; IN VIVO; NEUTRON BEAMS; PARTICLE BEAMS; PROTON BEAMS; RADIOTHERAPY; SENSITIVITY; SENSITIVITY ANALYSIS; THERMOLUMINESCENT DOSEMETERS
- Descriptors DEC
- BEAMS; DIAGRAMS; DOSEMETERS; INFORMATION; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; MEDICINE; NUCLEON BEAMS; PARTICLE BEAMS; THERAPY
Optional Information
- Notes
- Refs