Published December 1990
| Version v1
Report
Open
The analysis of 14.8 percent cold leg break without the application of hydroaccumulators in the PMK-NHV test facility
Description
A series of reactor safety tests have been performed in the experimental reactor simulation facility PMK-NHV of the Paks Nuclear Power Plant, Hungary, with and without the use of hydroaccumulator (SIT) operation. 14.8 percent cold leg break simulation experiments are reported without SITs in action, and the measurement results were analyzed using the RELAP5/mod2 computer code. The description of the experiment is followed by the parameter variations and their analysis, together with an interpretation of the measurement results. The lessons from the LOCA simulation tests are evaluated. (R.P.) 10 refs.; 48 figs.; 3 tabs
Availability note (English)
MF available from INIS under the Report Number.Files
22052017.pdf
Files
(1.4 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:bd8b73b17ab55c16d386ff5fa0275ee5
|
1.4 MB | Preview Download |
Additional details
Additional titles
- Original title (Hungarian)
- 14.8%-os hidegagi toeres analizise hidroakkumulatorok alkalmazasa nelkuel a PMK-NVH berendezesen
Publishing Information
- Imprint Pagination
- 94 p.
- Report number
- KFKI--1990-57/G
INIS
- Country of Publication
- Hungary
- Country of Input or Organization
- Hungary
- INIS RN
- 22052017
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- COMPUTERIZED SIMULATION; FRACTURES; LOSS OF COOLANT; R CODES; REACTOR COOLING SYSTEMS; REACTOR SAFETY EXPERIMENTS; REACTOR SIMULATORS
- Descriptors DEC
- ACCIDENTS; ANALOG SYSTEMS; COMPUTER CODES; COOLING SYSTEMS; FAILURES; FUNCTIONAL MODELS; REACTOR ACCIDENTS; REACTOR COMPONENTS; SIMULATION; SIMULATORS