The analysis of 14.8 percent cold leg break without the application of hydroaccumulators in the PMK-NHV test facility

Description

A series of reactor safety tests have been performed in the experimental reactor simulation facility PMK-NHV of the Paks Nuclear Power Plant, Hungary, with and without the use of hydroaccumulator (SIT) operation. 14.8 percent cold leg break simulation experiments are reported without SITs in action, and the measurement results were analyzed using the RELAP5/mod2 computer code. The description of the experiment is followed by the parameter variations and their analysis, together with an interpretation of the measurement results. The lessons from the LOCA simulation tests are evaluated. (R.P.) 10 refs.; 48 figs.; 3 tabs

Availability note (English)

MF available from INIS under the Report Number.

Files

22052017.pdf

Files (1.4 MB)

Name Size Download all
md5:bd8b73b17ab55c16d386ff5fa0275ee5
1.4 MB Preview Download

Additional details

Additional titles

Original title (Hungarian)
14.8%-os hidegagi toeres analizise hidroakkumulatorok alkalmazasa nelkuel a PMK-NVH berendezesen

Publishing Information

Imprint Pagination
94 p.
Report number
KFKI--1990-57/G