Published 1990 | Version v1
Journal article

Development of high resolution focusing collimators intended for nondestructive testing by the Compton scattering tomography technique

  • 1. Institut National des Sciences Appliquees (INSA), 69 - Villeurbanne (France)

Description

An original method for building high resolution focusing collimators with a great number of channels is described. The method consists of filling a mould with tungsten powder and impregnating it with a fluid epoxy resin, by pumping through the powder. The fine strips, used as cores for the channels, are then pulled out. The collimator that was built had 49 fine slots, all converging in one little bar-shaped volume, to convey x-ray photons from this volume to the entrance window of a large scintillation crystal detector. The collimator exhibits a very good precision of the relative positions of slots, allowing the volume V to be very sharply shaped. Use of this collimator for nondestructive testing by the Compton scattering tomography (CST) technique allowed us to detect plane defects down to 0.1 mm, inside composite plates. (author)

Additional details

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
41
Journal Issue
2
Series
Appl. Radiat. Isot.
Journal Page Range
199-205
CODEN
ARISE

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
21050366
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S07: ISOTOPES AND RADIATION SOURCES;
Descriptors DEI
COLLIMATORS; COMPTON SCATTERING TOMOGRAPHY; FABRICATION; NONDESTRUCTIVE TESTING; SPECIFICATIONS
Descriptors DEC
MATERIALS TESTING; TESTING; TOMOGRAPHY