Published February 2011 | Version v1
Journal article

Corrosion Level Measurement Technique for RC Wall Reinforcement Using Non-Destructive Test Methods

  • 1. Seoul National University of Science and Technology, Seoul (Korea, Republic of)

Description

In order to measure corrosion level of reinforcement rebar in RC structures, non-destructive test methods which are concrete surface current density method and infrared thermographic technique were employed to measure corrosion levels. Experimental test parameters were various levels of corrosion states(0, 1, 3, 5, 7% of weight loss) and concrete cover depth(30 mm, 40 mm) and two different reinforcing rebar arrangements. The larger amount of concrete surface current density, the higher corrosion level in reinforcement rebar. The laboratory conditions which are ambient temperature and humidity have negligible effect on the infrared thermographical data. After analysis of current density and temperature distribution from concrete surface, corrosion level of reinforcement rebar embedded in concrete can be measured qualitatively based on the amount of electric current and heat flux

Additional details

Publishing Information

Journal Title
Journal of the Korean Society for Nondestructive Testing
Journal Volume
31
Journal Issue
1
Series
13 refs, 14 figs, 4 tabs
Journal Page Range
p. 24-31
ISSN
1225-7842

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
42104120
Subject category
S42: ENGINEERING; S36: MATERIALS SCIENCE;
Descriptors DEI
CORROSION; HEAT FLUX; HUMIDITY; NONDESTRUCTIVE TESTING; TEMPERATURE DISTRIBUTION
Descriptors DEC
CHEMICAL REACTIONS; MATERIALS TESTING; MOISTURE; TESTING