Corrosion Level Measurement Technique for RC Wall Reinforcement Using Non-Destructive Test Methods
Creators
- 1. Seoul National University of Science and Technology, Seoul (Korea, Republic of)
Description
In order to measure corrosion level of reinforcement rebar in RC structures, non-destructive test methods which are concrete surface current density method and infrared thermographic technique were employed to measure corrosion levels. Experimental test parameters were various levels of corrosion states(0, 1, 3, 5, 7% of weight loss) and concrete cover depth(30 mm, 40 mm) and two different reinforcing rebar arrangements. The larger amount of concrete surface current density, the higher corrosion level in reinforcement rebar. The laboratory conditions which are ambient temperature and humidity have negligible effect on the infrared thermographical data. After analysis of current density and temperature distribution from concrete surface, corrosion level of reinforcement rebar embedded in concrete can be measured qualitatively based on the amount of electric current and heat flux
Additional details
Publishing Information
- Journal Title
- Journal of the Korean Society for Nondestructive Testing
- Journal Volume
- 31
- Journal Issue
- 1
- Series
- 13 refs, 14 figs, 4 tabs
- Journal Page Range
- p. 24-31
- ISSN
- 1225-7842
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 42104120
- Subject category
- S42: ENGINEERING; S36: MATERIALS SCIENCE;
- Descriptors DEI
- CORROSION; HEAT FLUX; HUMIDITY; NONDESTRUCTIVE TESTING; TEMPERATURE DISTRIBUTION
- Descriptors DEC
- CHEMICAL REACTIONS; MATERIALS TESTING; MOISTURE; TESTING