Published April 2016 | Version v1
Book

The main feed water system control valve of nuclear power leakage defect analysis and measures

  • 1. China Nuclear Power Investment Co., Ltd., Jiaxing (China)

Description

Regulating valve plant main feed system is composed of the main valve and bypass valve, in order to adjust the water level of steam generator, during the period of unit operation, often appear this kind of valve media from the valve stem leakage phenomenon, cause great hidden trouble to the safe and stable operation of the unit, according to the principle of the valve stem seal, analyzes the cause of leakage, is put forward to V graphite packing with carbon fiber woven packing combined way of packing, the chemical properties of the materials and physical properties can satisfy the requirements of nuclear grade, combined with proper installation, finally solve the defect of the packing seal leakage. (authors)

Part of:
Progress report on nuclear science and technology in China (Vol.4). Proceedings of academic annual meeting of China Nuclear Society in 2015, No.2--nuclear energy & power sub-volume

Additional details

Publishing Information

Publisher
Atomic Energy Press
Imprint Place
Beijing (China)
ISBN
978-7-5022-7103-9
Imprint Title
Progress report on nuclear science and technology in China (Vol.4). Proceedings of academic annual meeting of China Nuclear Society in 2015, No.2--nuclear energy & power sub-volume
Imprint Pagination
377 p.
Journal Page Range
p. 84-88

Conference

Title
2015 academic annual meeting of China Nuclear Society
Dates
21-24 Sep 2015
Place
Mianyang (China)

Optional Information

Notes
4 figs., 2 tabs., 16 refs.