Published September 1994 | Version v1
Journal article

Laminated primary ceiling barriers for medical accelerator rooms

  • 1. Emory Clinic, Atlanta, GA (United States). Dept. of Radiation Ontology

Description

In this work the performance of a number of laminated shields used as the primary ceiling barrier for high-energy accelerator rooms was investigated. The neutron and photon dose equivalent rates were measured outside each shield. Based on the measured photon level and the calculated x-ray leakage level the dose equivalent rate due to photons produced by neutron interactions with the shield materials was estimated. Shielding parameters for polyethylene were established for photons and neutrons. It was found that the barriers designed using the techniques given in an NCRP report suffered from excessive radiation leakage. (author)

Additional details

Publishing Information

Journal Title
Physics in Medicine and Biology
Journal Volume
39
Journal Issue
9
Journal Page Range
p. 1331-1336.
ISSN
0031-9155
CODEN
PHMBA7

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
26052821
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ACCELERATORS; BUILDING MATERIALS; BUILDINGS; COMPARATIVE EVALUATIONS; COMPOSITE MATERIALS; HOSPITALS; RADIOTHERAPY; SHIELDING MATERIALS
Descriptors DEC
EVALUATION; MATERIALS; MEDICAL ESTABLISHMENTS; MEDICINE; THERAPY