Published June 2016 | Version v1
Journal article

SU-D-209-04: Raise Your Table: An Effective Way to Reduce Radiation Dose for Fluoroscopy

  • 1. University of Florida, Gainesville, FL (United States)

Description

Purpose: Patient table height plays an important role in estimating patient skin dose for interventional radiology (IR) procedures, because the patient's skin location is dependent on the height of table. Variation in table height can lead to as much as 150% difference in skin dose for patient exams with similar air kerma meter readings. In our facility, IR procedural workflow was recently changed to require the IR physicians to confirm the patient table height before the procedure. The patient table height data was collected before and after this workflow change to validate the implementation of this practice. Methods: Table height information was analyzed for all procedures performed in three IR rooms, which were impacted by the workflow change, covering three months before and after the change (Aug 2015 to Jan 2016). In total, 442, 425, and 390 procedures were performed in these three rooms over this time period. There were no personnel or procedure assignment changes during the six-month period of time. Statistical analysis was performed for the average table height changes before and after the workflow change. Results: For the three IR rooms investigated, after the workflow change, the average table heights were increased by 1.43 cm (p=0.004084), 0.66 cm (p=0.187089), and 1.59 cm (p=0.002193), providing a corresponding estimated skin dose savings of 6.76%, 2.94% and 7.62%, respectively. After the workflow change, the average table height was increased by 0.95 cm, 0.63 cm, 0.55 cm, 1.07 cm, 1.12 cm, and 3.36 cm for the six physicians who routinely work in these three rooms. Conclusion: Consistent improvement in table height settings has been observed for all IR rooms and all physicians following a simple workflow change. This change has led to significant patient dose savings by making physicians aware of the pre-procedure table position.

Additional details

Identifiers

Publishing Information

Journal Title
Medical Physics
Journal Volume
43
Journal Issue
6
Journal Page Range
vp.
ISSN
0094-2405
CODEN
MPHYA6

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
48071903
Subject category
S60: APPLIED LIFE SCIENCES;
Descriptors DEI
FLUOROSCOPY; HEIGHT; KERMA; PATIENTS; PERSONNEL; RADIATION DOSES; RADIOMETERS; SKIN
Descriptors DEC
BIOMEDICAL RADIOGRAPHY; BODY; DIAGNOSTIC TECHNIQUES; DIMENSIONS; DOSES; MEASURING INSTRUMENTS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIATION DETECTORS; RADIOLOGY

Optional Information

Notes
(c) 2016 American Association of Physicists in Medicine